top of page

SIE PRODUCTS

We aim for the best quality and precision.

AC890PX  /  AC Drives

Power Entry Types

Open View
Top Power Entry Version

Product Overview
AC890PX

High Power Modular AC Drives

The BUILDING BLOCK Drive

AC890PX modules plug into a common
bus rail system to form a COMPLETE DRIVE - enclosure, disconnect, line reactor and fusing

Features

Plug-in Modularity

  • Sealed modules are easy to install and service

  • PowerPak modules replace in minutes

  • Easy-to-handle-under 50 pounds

  • Replaceable by unskilled technicians

Integrated Bus System

  • Power wiring minimized

  • Keyed modules eliminate errors

Compact Size

  • Saves factory floor space

  • Only 20"(500mm) wide-Best-in-Class!

Industrially Rugged

  • Built-in Full Torque Braking

  • 4-quadrant dynamic response

  • Duty-cycle limited Braking resistor

  • Each bay location holds 1 PowerPak module

  • PowerPak modules include Inverter phase assemblies, DC supplies, and capacitor modules

  • Bus bars run across the PowerPak module back, with selfaligning, silver-plated plug-and-play connectors

  • Cooling fans draw air in the front and out a top plenum

  • Integrally mounted in a 79.7”(2024mm) high x 24.4”(620mm) deep x 19.7”(500mm) wide enclosure

 

Technical Specifications

  • Overload
    Standard Duty Torque Ratings: 110% for 60 seconds
    Heavy Duty Torque Ratings: 150% for 60 seconds
    Servo Torque Ratings: Consult Factory

  • Output Frequency
    0 -1000 Hz; V/Hz mode
    0 - 350 Hz; closed loop vector mode
    0 - 120 Hz; sensorless vector mode

  • Switching Frequency
    2 kHz (standard default), or 4* KHz (de-rating may apply)
    Audibly silent switching frequency pattern

  • Dynamic Braking
    Built-in DB switch and DB Resistor Standard, 100% Torque rated (limited duty)
    Option for external resistor

  • Operating Temperature
    0°C to 40°C (32°F to 104°F)

  • Product Enclosure Rating
    IP21/NEMA1 – Standard IP52 and higher
    available as special order

  • Enclosure Rating
    Enclosure to provide 15dB attenuation to radiated emissions between 30-100MHz.

  • Humidity

       Maximum 90% relative humidity at 40°C non-  condensing

  • Atmosphere

       Non flammable, non corrosive and dust free

  • Climactic Conditions

       Class 3k3, as defined by EN50178 (1998)

  • Vibration
    Test Fc of EN60068-2-6

 

International Standards

  • Pollution Degree
    Pollution Degree ll (non-conductive pollution, except for temporary condensation)

  • Europe
    This product conforms with the Low Voltage Directive 73/23/EEC with amendment
    93/68/EEC, Article 13 and Annex III using EN50178 (1998) to show compliance. Meets  EN61800-3 (2ndenvironment)

  • North America/Canada
    Complies with the requirements of UL508C

Product Manuals
AC890PX
Contact Us
Need help?
Ask our qualified specialists.